Rectifiers with distribution and sectioning
Rectifiers with division are used in operational current blocking cabinets

SHOT-U_OUTPUT-I_OUTPUT-N_OUTPUT-UKHL4 SINGLE-CHANNEL OPERATING CURRENT CABINET
The cabinet is equipped with an LCD display and LED indication on the door, indication of the state of switching devices, RS485 ModBus RTU interface, discrete status outputs. Contains one step-down low-frequency transformer, protective input and output circuit breakers (can be optionally replaced with a disconnector), a rectifier power unit, a reverse diode (parallel operation is allowed).

SHOT-U_OUTPUT-I_OUTPUT-N_OUTPUT-D-UKHL4 TWO-CHANNEL OPERATIONAL CURRENT CABINET
The cabinet is equipped with an LCD display and LED indication on the door, indication of the state of switching devices, RS485 ModBus RTU interface, discrete status outputs. Contains one step-down low-frequency transformer, protective input and output circuit breakers (can be optionally replaced with a disconnector), 2 rectifier power units, 2 independent control systems, reverse diodes.

SHOT-U_OUTPUT-I_OUTPUT-N_OUTPUT-DN-UKHL4 OPERATIONAL CURRENT CABINET WITH TWO INDEPENDENT CHANNELS
The cabinet is equipped with an LCD display and LED indication on the door, indication of the state of switching devices, RS485 ModBus RTU interface, discrete status outputs. Contains two step-down low-frequency transformers, protective input and output circuit breakers (can be optionally replaced with a disconnector), 2 rectifier power units, 2 independent control systems, reverse diodes.

SHOT-U_OUTPUT-I_OUTPUT-N_OUTPUT-RS-UKHL4SCH OPERATING CURRENT CABINET WITH AVR
The cabinet is equipped with an LCD display and LED indication on the door, indication of the state of switching devices, RS485 ModBus RTU interface, discrete status outputs. Contains a backup network input unit, one step-down low-frequency transformer, protective input and output circuit breakers (can be optionally replaced with a disconnector), a rectifier power unit, and a reverse diode.

SHOT-U_OUTPUT-I_OUTPUT-N_OUTPUT-D-RS-UKHL4 TWO-CHANNEL OPERATIONAL CURRENT CABINET WITH AVR
The cabinet is equipped with an LCD display and LED indication on the door, indication of the state of switching devices, RS485 ModBus RTU interface, discrete status outputs. Contains a backup network input unit, one step-down low-frequency transformer, protective input and output circuit breakers (can optionally be replaced with a disconnector), 2 rectifier power units, 2 independent control systems, reverse diodes

SHOT-U_OUTPUT-I_OUTPUT-N_OUTPUT-S-UKHL4SCHKAF OPERATING CURRENT SINGLE-CHANNEL SECTIONAL
The cabinet is equipped with an LCD display and LED indication on the door, indication of the state of switching devices, RS485 ModBus RTU interface, discrete status outputs. Contains an external current control unit AB (optionally voltage), one step-down low-frequency transformer, protective input and output circuit breakers (optionally can be replaced with a disconnector), power units rectifier, independent control systems, reverse diodes.

SHOT-U_OUTPUT-I_OUTPUT-N_OUTPUT-D-S-UKHL4 TWO-CHANNEL SECTIONAL OPERATING CURRENT CABINET
The cabinet is equipped with an LCD display and LED indication on the door, indication of the state of switching devices, RS485 ModBus RTU interface, discrete status outputs. Contains an external AB current control unit (optionally voltage), a backup network input unit, one step-down LF transformer, protective input and output circuit breakers (optionally can be replaced with a disconnector), a rectifier power unit, a reverse diode.